Image-Conditioned Diffusion for Privacy-Preserving Synthetic Medical Images
Abstract
Medical imaging models depend on large, shareable datasets, yet privacy constraints limit data dissemination. Current text-conditioned diffusion models fail to preserve subtle, distributed clinical signals, such as continuous physiological biomarkers, rendering synthetic data insufficient for robust downstream physiological modeling. Here, we evaluate image-to-image (I2I) diffusion as a tunable, privacy-preserving transformation that produces a synthetic counterpart of real images while preserving downstream-relevant information. We fine-tune Stable Diffusion with low-rank adapters on retinal fundus photographs and chest radiographs, assessing fidelity, clinical signal preservation, cross-site transfer, and empirical re-identification risk. I2I consistently outperforms text-to-image generation in image fidelity and in preserving biomarker information. In cross-cohort transfer to an external retinal dataset from the UK Biobank, pretraining on I2I synthetic data performs comparably to real-image pretraining and surpasses it in the smallest fine-tuning sets. Varying I2I strength reveals that the privacy–utility tradeoff is highly modality-dependent: while retinal images achieve practical de-identification, chest X-rays exhibit structural combinatorics that leave them substantially re-identifiable even at high noise strengths, exposing critical boundaries for diffusion-based anonymization. These results position image-conditioned diffusion as a practical approach for generating…
How strong is the evidence?
Evidence Hub reads this as a cohort study. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence.
Read the paper
Related studies
- Learning from First-Generation Qualitative Approaches in the IS Discipline: An Evolutionary View and Some Implications for Authors and Evaluators (PART 1/2)
- Commentary on the clinical and preclinical dosage limits of interstitially administered magnetic fluids for therapeutic hyperthermia based on current practice and efficacy models
- Prosthesis: New Technological Opportunities and Innovative Biomedical Devices
- The history and future of neural modeling for cochlear implants
- Ryanodine receptors: waking up from refractoriness
- Novel Transgenic Rabbit Model Sheds Light on the Puzzling Role of Matrix Metalloproteinase-12 in Atherosclerosis
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.