Intravoxel Incoherent Motion MR Imaging for Staging of Hepatic Fibrosis
Abstract
OBJECTIVES: To determine the potential of intravoxel incoherent motion (IVIM) MR imaging for staging of hepatic fibrosis (HF).
METHODS: We searched PubMed and EMBASE from their inception to 31 July 2015 to select studies reporting IVIM MR imaging and HF staging. We defined F1-2 as non-advanced HF, F3-4 as advanced HF, F0 as normal liver, F1 as very early HF, and F2-4 as significant HF. Then we compared stage F0 with F1, F0-1 with F2-3, and F1-2 with F3-4 using IVIM-derived parameters (pseudo-diffusion coefficient D*, perfusion fraction f, and pure molecular diffusion parameter D). The effect estimate was expressed as a pooled weighted mean difference (WMD) with 95% confidence interval (CI), using the fixed-effects model.
RESULTS: Overall, we included six papers (406 patients) in this study. Significant differences in D* were observed between F0 and F1, F0-1 and F2-3, and F1-2 and F3-4 (WMD 2.46, 95% CI 0.83-4.09, P = 0.006; WMD 13.10, 95% CI 9.53-16.67, P < 0.001; WMD 14.34, 95% CI 10.26-18.42, P < 0.001, respectively). Significant differences in f were also found between F0 and F1, F0-1 and F2-3, and F1-2 and F3-4 (WMD 1.62, 95% CI 0.06-3.18, P = 0.027; WMD 5.63, 95% CI 2.74-8.52, P < 0.001; WMD 3.30, 95% CI 2.10-4.50, P < 0.001, respectively). However, D showed no differences between F0 and F1, F0-1 and F2-3, and F1-2 and F3-4 (WMD 0.05, 95% CI -0.01─0.11, P = 0.105; WMD 0.04, 95% CI -0.01─0.10, P = 0.230; WMD 0.02, 95% CI -0.02─0.06, P = 0.378, respectively).
CONCLUSIONS:…
How strong is the evidence?
Evidence Hub reads this as a meta-analysis, done in people. Its evidence level is 1 of 5 (Highest · pooled evidence). Pooled evidence from several studies sits at the top of the evidence pyramid. Reported size: 406 participants or records.
Read the paper
Related studies
- Learning from First-Generation Qualitative Approaches in the IS Discipline: An Evolutionary View and Some Implications for Authors and Evaluators (PART 1/2)
- Commentary on the clinical and preclinical dosage limits of interstitially administered magnetic fluids for therapeutic hyperthermia based on current practice and efficacy models
- Prosthesis: New Technological Opportunities and Innovative Biomedical Devices
- The history and future of neural modeling for cochlear implants
- Ryanodine receptors: waking up from refractoriness
- Novel Transgenic Rabbit Model Sheds Light on the Puzzling Role of Matrix Metalloproteinase-12 in Atherosclerosis
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.