Magnetic resonance imaging in experimental stroke and comparison with histology: systematic review and meta-analysis
Abstract
BACKGROUND AND PURPOSE: Because the new era of preclinical stroke research demands improvements in validity and generalizability of findings, moving from single site to multicenter studies could be pivotal. However, the conduct of magnetic resonance imaging (MRI) in stroke remains ill-defined. We sought to assess the variability in the use of MRI for evaluating lesions post stroke and to examine the possibility as an alternative to gold standard histology for measuring the infarct size.
METHODS: We identified animal studies of ischemic stroke reporting lesion sizes using MRI. We assessed the degree of heterogeneity and reporting of scanning protocols, postprocessing methods, study design characteristics, and study quality. Studies performing histological evaluation of infarct size were further selected to compare with corresponding MRI using meta-regression.
RESULTS: Fifty-four articles undertaking a total of 78 different MRI scanning protocols met the inclusion criteria. T2-weighted imaging was most frequently used (83% of the studies), followed by diffusion-weighted imaging (43%). Reporting of the imaging parameters was adequate, but heterogeneity between studies was high. Twelve studies assessed the infarct size using both MRI and histology at corresponding time points, with T2-weighted imaging-based treatment effect having a significant positive correlation with histology (; P<0.001).
CONCLUSIONS: Guidelines for standardized use and reporting of MRI in preclinical stroke…
How strong is the evidence?
Evidence Hub reads this as a meta-analysis, done in animal, not in people. Its evidence level is 5 of 5 (Very low · case / narrative / animal / in vitro / in silico). Case reports, narrative reviews, and animal, cell or computer-model studies give the weakest evidence for human health.
Read the paper
Related studies
- Learning from First-Generation Qualitative Approaches in the IS Discipline: An Evolutionary View and Some Implications for Authors and Evaluators (PART 1/2)
- Commentary on the clinical and preclinical dosage limits of interstitially administered magnetic fluids for therapeutic hyperthermia based on current practice and efficacy models
- Prosthesis: New Technological Opportunities and Innovative Biomedical Devices
- The history and future of neural modeling for cochlear implants
- Ryanodine receptors: waking up from refractoriness
- Novel Transgenic Rabbit Model Sheds Light on the Puzzling Role of Matrix Metalloproteinase-12 in Atherosclerosis
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.