Abstract
Objective: The objective of our study was to estimate and compare the performance of diffusion-weighted imaging (DWI) with other MRI techniques including T2-weighted MRI for the detection of prostate cancer.
Materials and methods: Searches of the PubMed and Scopus electronic databases for the terms "prostate," "cancer," "diffusion-weighted imaging," and "magnetic resonance imaging" using an end date of December 2010 were completed. All included studies had histopathologic correlation; 2×2 contingency data were constructed for each study. A Bayesian receiver operating characteristic (ROC) model was used across studies to determine sensitivity, specificity, and area under the full or partial ROC curve.
Results: Nineteen articles consisting of a total of 5892 lesions were analyzed. Based on a 95% credible interval, DWI alone yielded a significantly better area under the ROC curve, sensitivity, and specificity (0.85, 0.69, 0.89, respectively) than T2-weighted imaging alone (0.75, 0.60, 0.76). Combined DWI and T2-weighted imaging (0.73, 0.70, 0.83) showed a similar area under the ROC curve but significantly better sensitivity and specificity than T2-weighted imaging alone. DWI and combined DWI and T2-weighted imaging yielded similar overall sensitivity, but DWI alone showed better overall specificity than combined DWI and T2-weighted imaging. At specificities of greater than 80%, combined DWI and T2-weighted imaging yielded a partial area under the ROC curve (0.138) similar to…
How strong is the evidence?
Evidence Hub reads this as a meta-analysis, done in people. Its evidence level is 1 of 5 (Highest · pooled evidence). Pooled evidence from several studies sits at the top of the evidence pyramid.
Read the paper
Related studies
- Learning from First-Generation Qualitative Approaches in the IS Discipline: An Evolutionary View and Some Implications for Authors and Evaluators (PART 1/2)
- Commentary on the clinical and preclinical dosage limits of interstitially administered magnetic fluids for therapeutic hyperthermia based on current practice and efficacy models
- Prosthesis: New Technological Opportunities and Innovative Biomedical Devices
- The history and future of neural modeling for cochlear implants
- Ryanodine receptors: waking up from refractoriness
- Novel Transgenic Rabbit Model Sheds Light on the Puzzling Role of Matrix Metalloproteinase-12 in Atherosclerosis
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.