AI unleashed: A meta-analysis transforming radiological insights in diagnosing abdominal infections
Abstract
INTRODUCTION
Artificial intelligence (AI)-based imaging modalities are next-generation diagnostic devices for abdominal infections that promise to provide enhanced diagnostic speed and accuracy. This systematic review and meta-analysis critically analyze the diagnostic accuracy of AI-assisted imaging modalities, including for appendicitis, pneumoperitoneum, and cholecystitis, to present a balanced estimate of their clinical utility.
METHODS
A systematic literature search was undertaken in PubMed, Scopus, and Cochrane databases to search for studies that assessed the diagnostic accuracy of AI-based imaging modalities for abdominal infections. Eleven studies were included based on the inclusion criteria, and data were pooled for analysis. Diagnostic performance was measured by estimating sensitivity, specificity, likelihood ratios, diagnostic odds ratio (DOR), and area under the curve (AUC) using a random-effects model. Subgroup analyses were done to investigate the effect of infection type on diagnostic accuracy.
RESULTS
AI-assisted imaging demonstrated an overall sensitivity of 0.891 (95% CI: 0.824-0.944) and specificity of 0.860 (95% CI: 0.784-0.922) for diagnosing abdominal infections. Subgroup analysis revealed that AI-aided computed tomography (CT) exhibited a sensitivity of 0.902 (95% CI: 0.850-0.948), while ultrasound (US) showed a sensitivity of 0.864 (95% CI: 0.792-0.922). The highest AUCs were observed for pneumoperitoneum (0.985) and appendicitis (0.947),…
How strong is the evidence?
Evidence Hub reads this as a meta-analysis. Its evidence level is 1 of 5 (Highest · pooled evidence). Pooled evidence from several studies sits at the top of the evidence pyramid.
Read the paper
Related studies
- Learning from First-Generation Qualitative Approaches in the IS Discipline: An Evolutionary View and Some Implications for Authors and Evaluators (PART 1/2)
- Commentary on the clinical and preclinical dosage limits of interstitially administered magnetic fluids for therapeutic hyperthermia based on current practice and efficacy models
- Prosthesis: New Technological Opportunities and Innovative Biomedical Devices
- The history and future of neural modeling for cochlear implants
- Ryanodine receptors: waking up from refractoriness
- Novel Transgenic Rabbit Model Sheds Light on the Puzzling Role of Matrix Metalloproteinase-12 in Atherosclerosis
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.