Meta-analysis of quantitative diffusion-weighted MR imaging in the differential diagnosis of breast lesions
Abstract
BackgroundTo determine, in a meta-analysis, the diagnostic performance of quantitative diffusion-weighted (DW) MR imaging in patients with breast lesions.MethodsEnglish and Chinese studies published prior to June 2009 to assess the diagnostic performance of quantitative DWI in patients with breast lesions were reviewed and summarized with reference to the inclusion and exclusion criteria. Methodological quality was assessed by using the quality assessment of diagnostic studies (QUADAS) instrument. Publication bias analysis was performed by using Comprehensive Meta-analysis version 2. Meta-Disc version 1.4 was used to describe primary results and explore homogeneity by Chi-square test and inconsistency index; to explore threshold effect by receiver operator characteristic (ROC) space and Spearman correlation coefficient; and to pool weighted sensitivity and specificity by fixed or random effect model. A summary ROC (sROC) curve was constructed to calculate the area under the curve (AUC).ResultsOf 65 eligible studies, 13 with 615 malignant and 349 benign lesions were included in the original meta-analysis, among which heterogeneity arising from factors other than threshold effect and publication bias was explored. Methodological quality was moderate. The pooled weighted sensitivity and specificity with corresponding 95% confidence interval (CI) in one homogenous subgroup of studies using maximum b = 1000 s/mm2 were 0.84 (0.80, 0.87) and 0.84 (0.79, 0.88) respectively. AUC of…
How strong is the evidence?
Evidence Hub reads this as a meta-analysis. Its evidence level is 1 of 5 (Highest · pooled evidence). Pooled evidence from several studies sits at the top of the evidence pyramid.
Read the paper
Related studies
- Learning from First-Generation Qualitative Approaches in the IS Discipline: An Evolutionary View and Some Implications for Authors and Evaluators (PART 1/2)
- Commentary on the clinical and preclinical dosage limits of interstitially administered magnetic fluids for therapeutic hyperthermia based on current practice and efficacy models
- Prosthesis: New Technological Opportunities and Innovative Biomedical Devices
- The history and future of neural modeling for cochlear implants
- Ryanodine receptors: waking up from refractoriness
- Novel Transgenic Rabbit Model Sheds Light on the Puzzling Role of Matrix Metalloproteinase-12 in Atherosclerosis
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.