Evidence Hub

Impact of a quality control circle on the incidence of catheter-associated urinary tract infection: An interrupted time series analysis

Xiao Zhong, Li-Hua Xiao, Dong-Li Wang, Shan Yang, Lan-Fang Mo, Lan-Fang He, Qing-Fei Wu, Yan-Wei Chen et al.

American Journal of Infection Control, 2020

9 citations

Abstract

BACKGROUND

To report a quality control circle (QCC) activity on the theme of reducing the incidence of catheter-associated urinary tract infection (CAUTI), and used an interrupted time series analysis to evaluate the impact of the QCC.

METHODS

In a general tertiary hospital in Shenzhen, China, we carried out a QCC activity with the theme of reducing CAUTI from April 2017 to December 2017. Before the QCC, we carried out the routine measures; during the QCC, we implemented usual measures and the countermeasures of QCC, and after the QCC, we performed the routine measures and adhered to the core measures of QCC. The interrupted time series analysis method was used to analyze the changes in the CAUTI incidence during the 3 stages.

RESULTS

Before, during, and after the QCC activities, the catheter use ratios and mean indwelling time both had a downward trend; meanwhile, the compliance rate of CAUTI prevention measures showed an upward trend. After the interventions, the CAUTI incidence decreased by 1.317‰ immediately, then gradually decreased by 0.510‰ per month. After the completion of QCC, the CAUTI incidence increased by 0.266‰ immediately and increased by 0.070‰ over time, but the difference was not statistically significant.

CONCLUSIONS

The CAUTI incidence is reduced through QCC, providing a useful reference for the prevention of CAUTI and the development of medical quality improvement activities.

Read the paper

Related studies

Go deeper in Evidence Hub

Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.