Favorable clinical outcomes of three-dimensional computer-optimized high-dose-rate prostate brachytherapy in the management of localized prostate cancer
Abstract
PURPOSE: To report PSA relapse-free survival and toxicity outcomes of prostate cancer patients who have undergone three-dimensional computer-optimized high-dose-rate (HDR) brachytherapy with external beam radiotherapy as definitive treatment.
METHODS AND MATERIALS: One hundred five patients consecutively treated between 1998 and 2004 are reported. All patients were treated with HDR boost with lr 192 (5.5-7.0 Gy), based upon postimplant CT three-dimensional treatment planning using an in-house treatment plan optimization algorithm. Three-dimensional conformal external beam radiotherapy (45-50.4 Gy) was also administered 3 weeks after the HDR procedure. Toxicity was measured using National Cancer Institutes Common Toxicity Criteria and International Prostate Symptom Score indices.
RESULTS: With a median followup of 44 months (8-79 months), the 5-year PSA relapse-free survival outcomes for low, intermediate and high-risk patients were 100%, 98%, and 92%, respectively, Median urinary toxicity, and 93% of patients denied rectal problems at the time of last followup. Erectile dysfunction was noted in 47% patients at the time of last followup, but overall 80% were able to achieve vaginal penetration when those who responded to sildenafil were included.
CONCLUSION: Computer-optimized three-dimensional HDR prostate brachytherapy provides excellent disease control for even high risk localized prostate cancer. Significant toxicity has been minimal.
How strong is the evidence?
Evidence Hub reads this as a cohort study, done in people. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence.
Read the paper
Related studies
- Drug repositioning: a brief overview
- Cyclic nucleotide phosphodiesterases in Drosophila melanogaster
- Time-resolved in silico modeling of fine-tuned cAMP signaling in platelets: feedback loops, titrated phosphorylations and pharmacological modulation
- Current View on Green Tea Catechins Formulations, Their Interactions with Selected Drugs, and Prospective Applications for Various Health Conditions
- In silico Structure-based Identification of Novel Acetylcholinesterase Inhibitors Against Alzheimer’s Disease
- Development and In Vitro Evaluation of Controlled Release Viagra® Containing Poloxamer-188 Using Gastroplus™ PBPK Modeling Software for In Vivo Predictions and Pharmacokinetic Assessments
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.