Evidence Hub

Performance of the Self-Controlled Case Series for Drug Safety Signal Detection: A Multi-Database Study

Coste A, Wong AYS, Haguinet F, Bate A, Douglas IJ

Pharmacoepidemiology and drug safety, 2026

1 citation

Abstract

Background: Differences in performance of the Self-Controlled Case Series (SCCS) for signal detection have been reported across different databases. However, there has been limited comparative analysis of performance and it remains unknown whether combinations of databases could enable more effective signal detection.

Objectives: This study aims to compare the performance of the SCCS for signal detection across several data sources, and to determine whether combinations of databases can improve SCCS performance.

Methods: We applied the SCCS to macrolides and fluoroquinolone antibiotics, in four databases: Merative MarketScan Commercial Claims and Medicare, the Clinical Practice Research Datalink (CPRD) Aurum and the Système National des Données de Santé. We developed a reference set of 104 positive controls and 58 negative controls, using a taxonomy framework to ensure the selected drug outcome pairs are theoretically well suited to the SCCS design. The observation period lasted 2 years, with a 30-day risk-window after each dispensing. Diagnostic performance was measured using sensitivity, specificity and area under the receiver operating curve (AUC) with respect to the product labels, both for individual and combinations of databases.

Results: The sensitivity of the SCCS ranged from 0.57-0.89 across individual databases, and the specificity from 0.43-0.77 when limited to drug-outcome pairs sufficiently powered. The combination of all databases achieved the maximum…

How strong is the evidence?

Evidence Hub reads this as a case series, done in people. Its evidence level is 5 of 5 (Very low · case / narrative / animal / in vitro / in silico). Case reports, narrative reviews, and animal, cell or computer-model studies give the weakest evidence for human health.

How the five levels of evidence work. The level is assigned automatically from the abstract and can be wrong, so check the paper.

Read the paper

Related studies

Go deeper in Evidence Hub

Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.

Open this study Sign up free