Follow-up Bone Mineral Density Testing: 2023 Official Positions of the International Society for Clinical Densitometry
Abstract
Dual-energy X-ray absorptiometry (DXA) is the gold standard method for measuring bone mineral density (BMD) which is most strongly associated with fracture risk. BMD is therefore the basis for the World Health Organization's densitometric definition of osteoporosis. The International Society for Clinical Densitometry (ISCD) promotes best densitometry practices and its official positions reflect critical review of current evidence by domain experts. This document reports new official positions regarding follow-up DXA examinations based on a systematic review of literature published through December 2022. Adoption of official positions requires consensus agreement from an expert panel following a modified RAND protocol. Unless explicitly altered by the new position statements, prior ISCD official positions remain in force. This update reflects increased consideration of the clinical context prompting repeat examination. Follow-up DXA should be performed with pre-defined objectives when the results would have an impact on patient management. Testing intervals should be individualized according to the patient's age, sex, fracture risk and treatment history. Incident fractures and therapeutic approach are key considerations. Appropriately ordered and interpreted follow-up DXA examinations support diagnostic and therapeutic decision making, thereby contributing to excellent clinical care. Future research should address the complementary roles of clinical findings, imaging and…
How strong is the evidence?
Evidence Hub reads this as a systematic review, done in people. Its evidence level is 1 of 5 (Highest · pooled evidence). Pooled evidence from several studies sits at the top of the evidence pyramid.
Read the paper
Related studies
- Development of a crushable foam model for human trabecular bone
- Data-driven motion compensation in HR-pQCT.
- Modeling of structure, quality, and function in the orthodontic patient
- Exploring the mechanism of Heidihuang Pill in the treatment of osteoporosis based on network pharmacology, molecular docking, and experimental validation
- Effect of fabric on the accuracy of computed tomography-based finite element analyses of the vertebra
- Use of interventions involving virtual reality tasks during the climacteric: a systematic review
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.