Dual-Energy CT-Based Bone Mineral Density Has Practical Value for Osteoporosis Screening around the Knee
Abstract
Introduction: Adequate bone quality is essential for long term biologic fixation of cementless total knee arthroplasty (TKA). Recently, vertebral bone quality evaluation using dual-energy computed tomography (DECT) has been introduced. However, the DECT bone mineral density (BMD) in peripheral skeleton has not been correlated with Hounsfield units (HU) or central dual-energy X-ray absorptiometry (DXA), and the accuracy remains unclear. Materials and methods: Medical records of 117 patients who underwent TKA were reviewed. DXA was completed within three months before surgery. DECT was performed with third-generation dual source CT in dual-energy mode. Correlations between DXA, DECT BMD and HU for central and periarticular regions were analyzed. Receiver operating characteristic (ROC) curves were plotted and area under the curve (AUC), optimal threshold, and sensitivity and specificity of each region of interest (ROI) were calculated. Results: Central DXA BMD was correlated with DECT BMD and HU in ROIs both centrally and around the knee (all p femur neck; DECT BMD > DECT HU, respectively). Using the DXA T-score at L2 as the reference standard, the optimal DECT BMD cut-off values for osteoporosis were 89.2 mg/cm3 in the distal femur and 78.3 mg/cm3 in the proximal tibia. Conclusion: Opportunistic volumetric BMD assessment using DECT is accurate and relatively simple, and does not require extra equipment. DECT BMD and HU are useful for osteoporosis screening before cementless…
How strong is the evidence?
Evidence Hub reads this as a cohort study, done in people. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence. Reported size: 117 participants or records.
Read the paper
Related studies
- Development of a crushable foam model for human trabecular bone
- Data-driven motion compensation in HR-pQCT.
- Modeling of structure, quality, and function in the orthodontic patient
- Exploring the mechanism of Heidihuang Pill in the treatment of osteoporosis based on network pharmacology, molecular docking, and experimental validation
- Effect of fabric on the accuracy of computed tomography-based finite element analyses of the vertebra
- Use of interventions involving virtual reality tasks during the climacteric: a systematic review
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.