High-performance liquid chromatography with diode array detection method for the simultaneous determination of seven selected phosphodiesterase-5 inhibitors and serotonin reuptake inhibitors used as male sexual enhancers
Abstract
This work presents a simple, sensitive and generic high-performance liquid chromatography with diode array detection method for the simultaneous determination of seven drugs prescribed for the treatment of erectile dysfunction and premature ejaculation. Investigated drugs include the phosphodiesterase-5 inhibitors: sildenafil, tadalafil, and vardenafil, in addition to the selective serotonin reuptake inhibitors: dapoxetine, duloxetine, fluoxetine, and paroxetine. The drugs were separated using a Waters C8 column (4.6 × 250 mm, 5 μm) with the mobile phase consisting of phosphate buffer pH 3, acetonitrile and methanol in the ratio 60:33:7. The flow rate was 1.2 mL/min, and quantification was based on measuring peak areas at 225 nm. Peaks were perfectly resolved with retention times 3.3, 3.9, 6.4, 7.5, 9.5, 10.7, and 13.4 min for vardenafil, sildenafil, paroxetine, duloxetine, dapoxetine, fluoxetine, and tadalafil, respectively. The developed method was validated with respect to system suitability, linearity, ranges, accuracy, precision, robustness, and limits of detection and quantification. The proposed method showed good linearity in the ranges 5-500, 2-200, 2-200, 3-300, 1.5-150, 2-200, and 2-200 μg/mL for sildenafil, tadalafil, vardenafil, dapoxetine, duloxetine fluoxetine, and paroxetine, respectively. The limits of detection were 0.18-0.38 μg/mL for the analyzed compounds. The applicability of the proposed method to real life situations was assessed through the analysis…
Read the paper
Related studies
- Understanding and treating ejaculatory dysfunction in men with diabetes mellitus
- An Eco-Friendly Solid-State Electrode Modified With ZnO Nanoparticles Decorated With MWCNT as an Electrochemical Sensor for the Determination of Avanafil in Pure Form, Dosage Form and Human Plasma
- Combinations of Freeze-Dried Amorphous Vardenafil Hydrochloride with Saccharides as a Way to Enhance Dissolution Rate and Permeability
- Return to Sport, Reinjury Rate, and Tissue Changes after Muscle Strain Injury: A Narrative Review
- 875: High Prevalence of Significant Comorbid Conditions in Men with Erectile Dysfunction: Momentus Trial Demonstrates Efficacy and Safety of Tadalafil in this Group
- Safety and efficacy of phosphodiesterase-5 (PDE-5) inhibitors in fetal growth restriction: a systematic literature review and meta-analysis
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.