Trigeminal Rhizotomy Performed with Modern Image-guided Linac: Case Report
Abstract
Introduction: There are substantive articles published within the last ten years describing the use of linear accelerator (Linac) based treatment of trigeminal neuralgia (TN). In this paper, we report a single case of a patient with classic TN successfully treated by radiosurgical rhizotomy using a modern image-guided linear accelerator with a high-definition multileaf collimator and an optically guided targeting system. The measurement of absolute dose prior to treatment greatly facilitated our confidence with radiosurgical lesioning. Materials and Methods: This 54-year-old patient had a six-year history of lancinating pain involving the lower third of the right face which dramatically intensified in December of 2012, shortly after beginning Vincristine. A treatment plan was generated using a nine-field dynamic arc technique. A target volume was placed at 2-3 mm from the root entry zone measuring 6 x 3 x 3 mm. The PTV dose was prescribed to 60 Gy to the 80% isodose line. Initial verification of absolute dose using Gafchromic film resulted in an increase of the planned MU's by 7.5%. Remeasurement improved the absolute dose to within ±2 % of the calculated dose. Results: The patient was evaluated two weeks and three months following treatment. Her trigeminal pain was 80% resolved after two weeks and 100% at the three-month evaluation. She required none of her chronic pre-treatment medications and demonstrated no clinically detected sensory deficits. Conclusions: Linear…
How strong is the evidence?
Evidence Hub reads this as a case report, done in people. Its evidence level is 5 of 5 (Very low · case / narrative / animal / in vitro / in silico). Case reports, narrative reviews, and animal, cell or computer-model studies give the weakest evidence for human health.
Read the paper
Related studies
- Lathyrism-induced alterations in collagen cross-links influence the mechanical properties of bone material without affecting the mineral
- High-Resolution SPECT-CT/MR Molecular Imaging of Angiogenesis in the Vx2 Model
- Severely impaired bone material quality in Chihuahua zebrafish resembles classical dominant human osteogenesis imperfecta
- Small-animal SPECT and SPECT/CT: application in cardiovascular research
- Intravital imaging of osteocytes in mouse calvaria using third harmonic generation microscopy
- Techniques and Evaluation From a Cross-Platform Imaging Comparison of Quantitative Ultrasound Parameters in an In Vivo Rodent Fibroadenoma Model
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.