Evidence Hub

Effectiveness of low frequency vibration on the rate of canine retraction: a randomized controlled clinical trial

Mohamed Atfy Abd ElMotaleb, A. El-Beialy, F. A. El-sharaby, Amr E. Eldakroury, Ahmed A. Eid

Scientific Reports, 2024

13 citations

Abstract

To investigate the effectiveness of AcceleDent Aura vibrating device on the rate of canine retraction. Thirty-two patients requiring extraction of upper first premolars and canine retraction were randomly allocated with a 1:1 ratio into either no-appliance group or the AcceleDent Aura appliance group. Canine retraction was done applying 150gm of retraction force using NiTi coil springs on 16 × 22 stainless steel archwires. The duration of the study was 4 months. Models were collected and digitized directly after extraction of upper first premolars and at monthly intervals during canine retraction for recording the monthly as well as the total distance moved by the canine. Digitized models were superimposed on the initial model and data were statistically analyzed. Anchorage loss, rotation, tipping, torque and root condition were evaluated using cone beam computed tomography imaging. Pain was evaluated by visual analog scale. No patients were dropped-out during this study. There was no statistically significant difference between both groups regarding the total distance travelled by the canine (P = 0.436), as well as the rate of canine retraction per month (P = 0.17). Root condition was the same for the two groups. Regarding the pain level, there was no statistically significant difference between the two groups at day 0 (P = 0.721), after 24 h (P = 0.882), after 72 h (P = 0.378) and after 7 days (P = 0.964). AcceleDent Aura was not able to accelerate orthodontic tooth…

How strong is the evidence?

Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 2 of 5 (High · randomized trial). Randomized trials of a reasonable size are the strongest single-study design.

How the five levels of evidence work. The level is assigned automatically from the abstract and can be wrong, so check the paper.

Read the paper

Related studies

Go deeper in Evidence Hub

Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.

Open this study Sign up free