Evidence Hub

Omega Plate Fixation of Comminuted Olecranon Fractures: Technique and Case Series

Khanna A, Clark CJ, Yuan BJ, Tangtiphaiboontana J, Barlow JD

Techniques in hand & upper extremity surgery, 2024

Abstract

Fixation of olecranon fractures, especially those with minimal proximal bone and those that present with significant comminution, can be technically challenging. Current open reduction and internal fixation (ORIF) methods, such as tension band wire (TBW) constructs, plate fixation (PF), and intramedullary screws (IMSF), have demonstrated high rates of reoperation and symptomatic implants. We present the omega plate technique, which utilizes a mini-fragment plate passed under the triceps tendon insertion, allowing maximal implant surface area contact with small, proximal olecranon fracture fragments. The mini-fragment plate is not placed on the dorsal subcutaneous border of the ulna, which allows it to capture medial and lateral fragments of cortical comminution and may contribute to less soft tissue irritation.

How strong is the evidence?

Evidence Hub reads this as a case series, done in people. Its evidence level is 5 of 5 (Very low · case / narrative / animal / in vitro / in silico). Case reports, narrative reviews, and animal, cell or computer-model studies give the weakest evidence for human health.

How the five levels of evidence work. The level is assigned automatically from the abstract and can be wrong, so check the paper.

Read the paper

Related studies

Go deeper in Evidence Hub

Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.

Open this study Sign up free