This study presents a rigorous three-dimensional (3D) computational fluid dynamics (CFD) investigation into the complex hydrodynamic characteristics of an external falling liquid film flowing over horizontal tubes, focusing on a representative unit of the shell-side of a spiral-wound heat exchanger (SWHE). The primary objective is to quantitatively analyze the synergistic influence of key operating and structural parametersnamely, Reynolds number (Re), tube outer diameter (D), and tube spacing (S)on the liquid film profile, coverage uniformity, and flow regime transition. A volume of fluid (VOF) model was established and validated to accurately track the gas-liquid interface. The analysis reveals three major findings: (1) Increasing the Reynolds number from Re = 300 to Re = 2000 drives a critical flow regime transition from a stable columnar flow dominated by viscous and gravitational forces to a highly dynamic fan flow. This transition significantly intensifies interfacial wave activity, which is quantified by a positive correlation between wave amplitude and Re. (2) An increase in tube diameter (D) promotes the concentration of the liquid film into distinct columns, decreasing film coverage uniformity and increasing local film thickness, as surface tension and inertia compete for liquid distribution across the larger surface. (3) The tube spacing (S) critically governs the hydrodynamics in the intertube region; an optimal spacing (S = 6 mm in this study) is identified…
Read the paper
Related studies
- eggNOG 5.0: a hierarchical, functionally and phylogenetically annotated orthology resource based on 5090 organisms and 2502 viruses
- Online Survival Analysis Software to Assess the Prognostic Value of Biomarkers Using Transcriptomic Data in Non-Small-Cell Lung Cancer
- OptiType: precision HLA typing from next-generation sequencing data
- Nicotinic Cholinergic System and COVID-19: In Silico Identification of an Interaction between SARS-CoV-2 and Nicotinic Receptors with Potential Therapeutic Targeting Implications
- Saccharomyces cerevisiae cells have three Omega class glutathione S-transferases acting as 1-Cys thiol transferases
- Hemolysis at low blood flow rates: in-vitro and in-silico evaluation of a centrifugal blood pump
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.