Abstract
Objective: The qualitative fit testing procedure would be challenging due to severe shortages, high cost, and unavailability of commercial fit test kits in the marketplaces during pandemics of respiratory infectious diseases. Assessment of alternatives for commercial fit test kits to be prepared for emergencies is critically required. This study aimed to investigate the feasibility of an alternative of the Accumed NF60 nebulizer for the Occupational Safety and Health Administration (OSHA)-approved Allegro nebulizer.
Methods: Thirty-two participants were randomly allocated to 6 filtering facepiece respirators (FFRs). They were qualitatively fit tested by both manual Allegro and automated Accumed NF60 nebulizers.
Results: There was no statistically significant difference between the Allegro and Accumed NF60 nebulizers by passing rates. The odds for passing fit testing using the Accumed NF60 nebulizer was similar to that of the Allegro one (odds ratio=1.0, 95% confidence interval [0.58-1.74]).
Conclusions: The Accumed NF60 nebulizer could be used as a cost-benefit substitute for the standard fit test nebulizers in the pandemic situation where there is a shortage and difficulty of access. It is more convenient, decreases the time investment, and reduces the contact stress in the operators' hands as it does not require squeezing the nebulizer bulb frequently. The test solutions' preparation and fit testing procedures on many personnel are more straightforward, efficient, and…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 2 of 5 (High · randomized trial). Randomized trials of a reasonable size are the strongest single-study design.
Read the paper
Related studies
- A Survey on Knowledge Graphs: Representation, Acquisition, and Applications
- Toxicity of nanomaterials
- The Human Gene Mutation Database: towards a comprehensive repository of inherited mutation data for medical research, genetic diagnosis and next-generation sequencing studies
- Halogen bonding (X‐bonding): A biological perspective
- Biofilm formation at the air–liquid interface by the Pseudomonas fluorescens SBW25 wrinkly spreader requires an acetylated form of cellulose
- Opioid Activation of Toll-Like Receptor 4 Contributes to Drug Reinforcement
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.