Evidence Hub

Physician-modified vascular plug for entry closure of a chronic aneurysmal aortic dissection

Nishide R, Ohki T, Shukuzawa K, Fukushima S, Ozawa H, Kasa K

Journal of vascular surgery cases and innovative techniques, 2026

Abstract

For patients with a chronic aneurysmal aortic dissection (CAAD), closure of all entries and reentries, leading to complete exclusion of the false lumen, likely results in shrinkage of the false lumen and aortic remodeling. One technique to interrupt the false lumen blood flow and achieve complete exclusion is to occlude the entry with a vascular plug. However, depending on the size and location of the target entry, sufficient occlusion of the entry and resolution of false lumen blood flow may not be achieved even if the vascular plug is placed in the expected position due to the porous nature of the plug. Herein, we present a technique for entry closure in CAAD using a physician-modified vascular plug, which combines the Amplatzer Vascular Plug and an expanded polytetrafluoroethylene prosthetic patch to create a water-tight seal. This technique enables effective and reliable entry closure in CAAD, even when the entry site is close to a vital side branch, such as the arch vessels and the mesenteric artery, and standard stent graft use is not possible.

How strong is the evidence?

Evidence Hub reads this as a case report, done in people. Its evidence level is 5 of 5 (Very low · case / narrative / animal / in vitro / in silico). Case reports, narrative reviews, and animal, cell or computer-model studies give the weakest evidence for human health.

How the five levels of evidence work. The level is assigned automatically from the abstract and can be wrong, so check the paper.

Read the paper

Related studies

Go deeper in Evidence Hub

Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.

Open this study Sign up free