Evidence Hub

"Squeaky Hip": Are Noises Important?

Lavernia A, Johnson K, Cook SD, Salkeld SL, Patron LP, Nolan L, Lavernia CJ

Arthroplasty today, 2026

Abstract

We report on an 82-year-old female who developed painless "squeaking" and a grinding sensation 23 years after a ceramic-on-metal total hip arthroplasty. Radiographs revealed linear wear through the polyethylene insert. During revision, we replaced the acetabular construct with a dual mobility system. Intraoperatively, the acetabular bone damage was significant but contained, and the ceramic head had atypical wear after the polyethylene liner broke and was articulating directly with the titanium shell. The metallosis in the surrounding tissue was surprisingly minimal despite direct ceramic-on-metal contact. At 1-year follow-up, the patient recovered excellent function with complete noise resolution. This case establishes the importance of "listening" to your joints. New onset noise in any bearings should prompt urgent evaluation, allowing for timely intervention before significant damage occurs.

How strong is the evidence?

Evidence Hub reads this as a case report, done in people. Its evidence level is 5 of 5 (Very low · case / narrative / animal / in vitro / in silico). Case reports, narrative reviews, and animal, cell or computer-model studies give the weakest evidence for human health.

How the five levels of evidence work. The level is assigned automatically from the abstract and can be wrong, so check the paper.

Read the paper

Related studies

Go deeper in Evidence Hub

Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.

Open this study Sign up free