Cassola N, Baptista-Silva JC, Nakano LC, Flumignan CD, Sesso R, Vasconcelos V, Carvas Junior N, Flumignan RL

The Cochrane database of systematic reviews, 2022

23 citations

Abstract

Background: Carotid artery stenosis is an important cause of stroke and transient ischemic attack. Correctly and rapidly identifying patients with symptomatic carotid artery stenosis is essential for adequate treatment with early cerebral revascularization. Doubts about the diagnostic value regarding the accuracy of duplex ultrasound (DUS) and the possibility of using DUS as the single diagnostic test before carotid revascularization are still debated.

Objectives: To estimate the accuracy of DUS in individuals with symptomatic carotid stenosis verified by either digital subtraction angiography (DSA), computed tomography angiography (CTA), or magnetic resonance angiography (MRA).

Search methods: We searched CRDTAS, CENTRAL, MEDLINE (Ovid), Embase (Ovid), ISI Web of Science, HTA, DARE, and LILACS up to 15 February 2021. We handsearched the reference lists of all included studies and other relevant publications and contacted experts in the field to identify additional studies or unpublished data.

Selection criteria: We included studies assessing DUS accuracy against an acceptable reference standard (DSA, MRA, or CTA) in symptomatic patients. We considered the classification of carotid stenosis with DUS defined with validated duplex velocity criteria, and the NASCET criteria for carotid stenosis measures on DSA, MRA, and CTA. We excluded studies that included < 70% of symptomatic patients; the time between the index test and the reference standard was longer than four weeks or…

How strong is the evidence?

Evidence Hub reads this as a meta-analysis, done in people. Its evidence level is 1 of 5 (Highest · pooled evidence). Pooled evidence from several studies sits at the top of the evidence pyramid.

How the five levels of evidence work. The level is assigned automatically from the abstract and can be wrong, so check the paper.

Read the paper

Related studies

Go deeper in Evidence Hub

Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.

Open this study Sign up free