Evidence Hub

A study of the applications of compton backscatter radiation

Q.O. Navarro, A. De Castro, Alfonso Gómez García, Josefino C. Comiso

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information), 1963

Abstract

The effects of scattering angle, source angle, source position, detector position, and gamma-ray energy on the intensity of backscatter radiation from Al, asbestos, glass, steel, plywood and G. I. sheets of various thicknesses were studied using the 662-kev gamma ray of Cs/sup 137/ as the radiation source. Intensity showed a minimum between 80 and 90 deg scattering angles, varied little with the source angle, and was proportional to the material density and thickness. The signal-to-background ratio increased as the source was brought nearer the scatterer or the detector was moved away from the scatterer. The 662- kev gamma was quite satisfactory for steel and Fe measurements; less so for thickness determination of Al, asbestos, and glass. (D.C.W.)

Read the paper

Related studies

Go deeper in Evidence Hub

Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.

Open this study Sign up free