Is myocardial fibrosis appropriately assessed by 2D strain derived integrated backscatter?
Abstract
Type of funding sources: None.
Calibrated integrated backscatter (cIBS) may be obtained from bidimensional (2D) strain echocardiography as a quantification measurement of myocardial ultrasound reflectivity. Increased collagen content of the myocardium modifies tissue reflectivity and cIBS is suggested as a marker of left ventricular (LV) fibrosis. However, its diagnostic accuracy is not established.
To assess the correlation between cIBS by 2D strain and LV myocardial fibrosis (MF), as evaluated by non-invasive imaging and histopathology.
Correlation study from a cohort of 157 patients with severe symptomatic aortic stenosis (AS) referred for surgical aortic valve replacement (AVR). Patients with complete preoperative transthoracic echocardiography, cardiac magnetic resonance (CMR) and endomyocardial biopsy (EMB) obtained from the anterior basal septum at the time of AVR were selected. Two groups of 30 patients were evaluated, with and without late gadolinium enhancement (LGE) at CMR. IBS was obtained at QRS peak in decibels (dB) from both parasternal long axis (PLAX) and apical three chamber (A3C) cine clips at Qanalysis (Figure 1A). cIBS was calculated by subtracting the pericardial intensity from the average of the anteroseptal and basal inferolateral wall values. Correlation analysis was performed for the whole group of patients with global and segmental (anterior basal septum) values of native T1 and extracellular volume (ECV), and EMB collagen volume fraction (CVF)…
How strong is the evidence?
Evidence Hub reads this as a cohort study, done in people. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence. Reported size: 157 participants or records.
Read the paper
Related studies
- Characterization and Analysis of Porosity and Pore Structures
- Practical considerations for conducting ecotoxicity test methods with manufactured nanomaterials: what have we learnt so far?
- Dental Optical Coherence Tomography
- Radiation-shielding concrete: A review of materials, performance, and the impact of radiation on concrete properties
- Testing entanglement of annihilation photons
- Calanus finmarchicus seasonal cycle and diapause in relation to gene expression, physiology, and endogenous clocks
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.