Upper-Level Instrumentation at C2 Versus C3 Does Not Influence Radiographic or Clinical Outcomes After Posterior Cervical Fusion
Abstract
STUDY DESIGN
Retrospective cohort study.
OBJECTIVE
To assess clinical and radiographic outcomes after posterior cervical decompression and fusion (PCDF) with upper instrumented vertebra (UIV) at C2 versus C3.
SUMMARY OF BACKGROUND DATA
PCDF is a common procedure for treatment of multilevel cervical spondylotic myelopathy. The evidence is sparse as to whether C2 versus C3 is the optimal UIV.
METHODS
Adult patients undergoing PCDF for cervical myelopathy from 2014 to 2019 at a single center were identified. Patients with UIV at C2 or C3 and LIV at or above T2 were included. Exclusion criteria included pediatric patients, revision procedures, staged procedures, and intervention for infectious, oncologic, or traumatic indications. Patients with incomplete follow-up (eg, <2 y postoperatively) were excluded from the final analysis. Demographic data, surgical characteristics, clinical outcomes, and radiographic outcomes were compared.
RESULTS
A total of 135 consecutive patients were included, of whom 47 (34.8%) had UIV at C2 and 88 (65.2%) had UIV at C3. There was no difference in 90-day readmission (14.9% vs. 20.5%, P=0.491) or 2-year reoperation between the groups (17.0% vs. 14.0%, P=0.628). The mean difference from baseline to final follow-up in cSVA, T1 slope, CL, TS-CL, and C0-C2 were similar between groups (P=0.753, 0.181, 0.797, 0.910, 0.959, respectively). Multivariate analysis did not reveal any correlation between UIV and radiographic outcomes (P>0.05).
CONCLUSIONS
There…
How strong is the evidence?
Evidence Hub reads this as a cohort study, done in people. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence. Reported size: 135 participants or records.
Read the paper
Related studies
- Characterization and Analysis of Porosity and Pore Structures
- Practical considerations for conducting ecotoxicity test methods with manufactured nanomaterials: what have we learnt so far?
- Dental Optical Coherence Tomography
- Radiation-shielding concrete: A review of materials, performance, and the impact of radiation on concrete properties
- Testing entanglement of annihilation photons
- Calanus finmarchicus seasonal cycle and diapause in relation to gene expression, physiology, and endogenous clocks
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.