Photon-counting CT versus energy-integrating detectors for cardiac imaging: a systematic review of evidence from in vivo human studies on image quality and radiation dose
Abstract
Computed tomography (CT) is central to cardiovascular diagnostics, with coronary CT angiography (CCTA) widely used for evaluating coronary artery disease (CAD) due to its high sensitivity and negative predictive value. However, conventional energy-integrating detector (EID) CT is limited by reduced contrast resolution and artifacts, especially in patients with heavy calcification or stents, which can impair diagnostic accuracy. Photon-counting CT (PCCT) is an emerging technology that directly converts X-ray photons into electrical signals, offering improved spatial resolution, contrast-to-noise ratio (CNR), and dose efficiency. While phantom studies have demonstrated its potential, clinical validation remains limited. This systematic review assesses image quality and radiation dose of PCCT versus EID in human in vivo cardiovascular imaging studies. A systematic literature search was conducted in PubMed and Embase following PRISMA guidelines. Studies comparing PCCT and EID in cardiovascular imaging in human patients were included. Outcomes of interest were image quality parameters (CNR, SNR, artifacts), subjective image quality, diagnostic confidence, and radiation dose metrics. Eleven studies met the inclusion criteria, encompassing a range of cardiovascular applications including CCTA, stent assessment, and coronary calcium scoring. Across studies, PCCT consistently demonstrated the potential to improve diagnostic image quality at similar radiation doses, or to maintain the…
How strong is the evidence?
Evidence Hub reads this as a systematic review, done in people. Its evidence level is 1 of 5 (Highest · pooled evidence). Pooled evidence from several studies sits at the top of the evidence pyramid.
Read the paper
Related studies
- Chaos and quantum thermalization
- The Dalton quantum chemistry program system
- Cord Blood Leptin and Adiponectin as Predictors of Adiposity in Children at 3 Years of Age: A Prospective Cohort Study
- Quantitative metabolomics by H-NMR and LC-MS/MS confirms altered metabolic pathways in diabetes
- Stable adiabatic quantum batteries
- A novel self-lipid antigen targets human T cells against CD1c(+) leukemias
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.