Evidence Hub

Absorbed Dose Determination for X-rays in the Grenz-ray Region (5 to 20 keV Quantum Energy)

ROBERT LOEVINGER, S.S. Yaniv

Physics in Medicine and Biology, 1965

9 citations

Abstract

Determination of the absorbed dose for very low-energy X-rays is greatly simplified by the absence of scattered radiation. Absorber thickness can be scaled from one material to another by use of a relative effective density , which is the ratio of the mass energy absorption coefficients. Depth dose functions can be transferred from one material to another and from one FSD to another, and can be corrected for changes in air absorption. Exposure in roentgens can be measured directly with a suitable extrapolation chamber. The Fricke ferrous sulphate dosemeter is readily applicable, and a value of G = 14·8 was found for a 50 kvp unfiltered X-ray beam from a beryllium-window tube. It is concluded that the properties of very low-energy X-rays do not necessarily add to the uncertainties inherent in all X-ray absorbed-dose determinations.