Dual-energy micro-focus computed tomography based on the energy-angle correlation of inverse Compton scattering source
Abstract
BACKGROUND: Inverse Compton scattering (ICS) source can produce quasi-monoenergetic micro-focus X-rays ranging from keV to MeV level, with potential applications in the field of high-resolution computed tomography (CT) imaging. ICS source has an energy-angle correlated feature that lower photon energy is obtained at larger emission angle, thus different photon energies are inherently contained in each ICS pulse, which is especially advantageous for dual- or multi-energy CT imaging.
OBJECTIVE: This study proposes a dual-energy micro-focus CT scheme based on the energy-angle correlation of ICS source and tests its function using numerical simulations.
METHODS: In this scheme, high- and low-energy regions are chosen over the angular direction of each ICS pulse, and dual-energy projections of the object are obtained by an angularly-splicing scanning method. The field-of-view (FOV) of ICS source is extended simultaneously through this scanning method, thus the scale of the imaging system can be efficiently reduced. A dedicated dual-energy CT algorithm is developed to reconstruct the monoenergetic attenuation coefficients, electron density, and effective atomic number distributions of the object.
RESULTS: A test object composed of different materials (carbon, aluminium, titanium, iron and copper) and line pairs with different widths (15/24/39/60 μm) is imaged by the proposed dual-energy CT scheme using numerical simulations, and high-fidelity monoenergetic attenuation coefficient,…
Read the paper
Related studies
- Developing high safety Li-metal anodes for future high-energy Li-metal batteries: strategies and perspectives
- Structure and Energy Transfer in Photosystems of Oxygenic Photosynthesis
- Ground- and Space-Based Gamma-Ray Astronomy
- Energy Functions in De Novo Protein Design: Current Challenges and Future Prospects
- Electronic structure of ions and molecules in solution: a view from modern soft X-ray spectroscopies
- Arising 2D Perovskites for Ionizing Radiation Detection
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.