Development of low-energy X-ray detectors using LGAD sensors
Abstract
Recent advances in segmented low-gain avalanche detectors (LGADs) make them promising for the position-sensitive detection of low-energy X-ray photons thanks to their internal gain. LGAD microstrip sensors fabricated by Fondazione Bruno Kessler have been investigated using X-rays with both charge-integrating and single-photon-counting readout chips developed at the Paul Scherrer Institut. In this work it is shown that the charge multiplication occurring in the sensor allows the detection of X-rays with improved signal-to-noise ratio in comparison with standard silicon sensors. The application in the tender X-ray energy range is demonstrated by the detection of the sulfur Kα and Kβ lines (2.3 and 2.46 keV) in an energy-dispersive fluorescence spectrometer at the Swiss Light Source. Although further improvements in the segmentation and in the quantum efficiency at low energy are still necessary, this work paves the way for the development of single-photon-counting detectors in the soft X-ray energy range.
Read the paper
Related studies
- Developing high safety Li-metal anodes for future high-energy Li-metal batteries: strategies and perspectives
- Structure and Energy Transfer in Photosystems of Oxygenic Photosynthesis
- Ground- and Space-Based Gamma-Ray Astronomy
- Energy Functions in De Novo Protein Design: Current Challenges and Future Prospects
- Electronic structure of ions and molecules in solution: a view from modern soft X-ray spectroscopies
- Arising 2D Perovskites for Ionizing Radiation Detection
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.