High-pitch, 120 kVp/30 mAs, low-dose dual-source chest CT with iterative reconstruction: Prospective evaluation of radiation dose reduction and image quality compared with those of standard-pitch low-dose chest CT in healthy adult volunteers
Abstract
Purpose: Objective of this study was to evaluate the effectiveness of the iterative reconstruction of high-pitch dual-source chest CT (IR-HP-CT) scanned with low radiation exposure compared with low dose chest CT (LDCT).
Materials and methods: This study was approved by the institutional review board. Thirty healthy adult volunteers (mean age 44 years) were enrolled in this study. All volunteers underwent both IR-HP-CT and LDCT. IR-HP-CT was scanned with 120 kVp tube voltage, 30 mAs tube current and pitch 3.2 and reconstructed with sinogram affirmed iterative reconstruction. LDCT was scanned with 120 kVp tube voltage, 40 mAs tube current and pitch 0.8 and reconstructed with B50 filtered back projection. Image noise, and signal to noise ratio (SNR) of the infraspinatus muscle, subcutaneous fat and lung parenchyma were calculated. Cardiac motion artifact, overall image quality and artifacts was rated by two blinded readers using 4-point scale. The dose-length product (DLP) (mGy∙cm) were obtained from each CT dosimetry table. Scan length was calculated from the DLP results. The DLP parameter was a metric of radiation output, not of patient dose. Size-specific dose estimation (SSDE, mGy) was calculated using the sum of the anteroposterior and lateral dimensions and effective radiation dose (ED, mSv) were calculated using CT dosimetry index.
Results: Approximately, mean 40% of SSDE (2.1 ± 0.2 mGy vs. 3.5 ± 0.3 mGy) and 34% of ED (1.0 ± 0.1 mSv vs. 1.5 ± 0.1 mSv) was reduced in…
How strong is the evidence?
Evidence Hub reads this as a clinical trial, done in people. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence.
Read the paper
Related studies
- Chaos and quantum thermalization
- The Dalton quantum chemistry program system
- Quantum dots: synthesis, bioapplications, and toxicity
- Cord Blood Leptin and Adiponectin as Predictors of Adiposity in Children at 3 Years of Age: A Prospective Cohort Study
- A Guide to In Silico Drug Design
- Quantitative metabolomics by H-NMR and LC-MS/MS confirms altered metabolic pathways in diabetes
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.