The Effectiveness of Intensity Modulated Radiation Therapy versus Three-Dimensional Radiation Therapy in Prostate Cancer: A Meta-Analysis of the Literatures
Abstract
BACKGROUND AND PURPOSE: Intensity modulated radiation therapy (IMRT) can deliver higher doses with less damage of healthy tissues compared with three-dimensional radiation therapy (3DCRT). However, for the scenarios with better clinical outcomes for IMRT than 3DCRT in prostate cancer, the results remain ambiguous. We performed a meta-analysis to assess whether IMRT can provide better clinical outcomes in comparison with 3DCRT in patients diagnosed with prostate cancer. MATERIALS AND METHODS: We conducted a meta-analysis of 23 studies (n = 9556) comparing the clinical outcomes, including gastrointestinal (GI) toxicity, genitourinary (GU) toxicity, biochemical controland overall survival (OS). RESULTS: IMRT was significantly associated with decreased 2-4 grade acute GI toxicity [risk ratio (RR) = 0.59 (95% confidence interval (CI), 0.44, 0.78)], late GI toxicity [RR = 0.54, 95%CI (0.38, 0.78)], late rectal bleeding [RR = 0.48, 95%CI (0.27, 0.85)], and achieved better biochemical control[RR = 1.17, 95%CI (1.08, 1.27)] in comparison with 3DCRT. IMRT and 3DCRT remain the same in regard of grade 2-4 acute rectal toxicity [RR = 1.03, 95%CI (0.45, 2.36)], late GU toxicity [RR = 1.03, 95%CI (0.82, 1.30)] and overall survival [RR = 1.07, 95%CI (0.96, 1.19)], while IMRT slightly increased the morbidity of grade 2-4 acute GU toxicity [RR = 1.08, 95%CI (1.00, 1.17)]. CONCLUSIONS: Although some bias cannot be ignored, IMRT appears to be a better choice for the treatment of prostate cancer…
How strong is the evidence?
Evidence Hub reads this as a meta-analysis. Its evidence level is 1 of 5 (Highest · pooled evidence). Pooled evidence from several studies sits at the top of the evidence pyramid. Reported size: 9,556 participants or records.
Read the paper
Related studies
- Quantum dots: synthesis, bioapplications, and toxicity
- A Guide to In Silico Drug Design
- Quantum Computing for Healthcare: A Review
- Automated in Silico Design of Homogeneous Catalysts
- Identification of Novel 3-Hydroxy-pyran-4-One Derivatives as Potent HIV-1 Integrase Inhibitors Using in silico Structure-Based Combinatorial Library Design Approach
- In silico structural elucidation of RNA-dependent RNA polymerase towards the identification of potential Crimean-Congo Hemorrhagic Fever Virus inhibitors
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.