Bone dimensional changes after flapless immediate implant placement with and without bone grafting: Randomized clinical trial
Abstract
INTRODUCTION
Immediate implant in postextraction sockets requires managing the postextraction alveolar resorption. This randomized clinical trial examined vertical and horizontal changes 1-year following flapless immediate implant with and without xenograft at sites with thin labial plate.
METHODS
Forty patients with hopeless teeth in maxillary esthetic zone were randomly assigned to receiving either one immediate implant without bone graft (control) or with bone graft (intervention). Cone beam computed tomography (CBCT) scans were obtained pre-extraction and 1-year postoperatively to measure thickness and dimensional changes of the labial bone.
RESULTS
Cone beam computed tomography measurements revealed that a xenograft, when compared to no xenograft, led to 0.2 mm increased fill of the horizontal gap (95% confidence interval (CI): -1.1, 0.7). In both groups, there was a significant reduction in the labio-palatal bone width after 1 year compared to baseline (P ≤ 0.05). There was no significant difference (P > 0.05) between the xenograft when compared to no xenograft regarding the labio-palatal bone collapse % at 0 mm (-0.2, 95% CI: -4.8, 4.5) and 2 mm apical to the labial crest (1.9, 95% CI: -1.8, 5.6). While at 5 mm the collapse was significantly reduced (P ≤ 0.05) in the no xenograft when compared to xenograft (4.5, 95% CI: 0.7, 8.2). The xenograft when compared to no xenograft, led to 1.1 mm less vertical bone changes (95% CI: 0.4, 1.9). Both groups revealed significant…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 2 of 5 (High · randomized trial). Randomized trials of a reasonable size are the strongest single-study design.
Read the paper
Related studies
- In silico toxicology protocols
- QM7-X, a comprehensive dataset of quantum-mechanical properties spanning the chemical space of small organic molecules
- Quantum Informed Machine-Learning Potentials for Molecular Dynamics Simulations of CO2's Chemisorption and Diffusion in Mg-MOF-74
- In-silico strategies in nano-drug design: Bridging nanomaterials and pharmacological applications
- mRNA codon optimization with quantum computers
- The computational power of the human brain
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.