Simulation study of comparative dosimetric analysis of coplanar horizontal-port scanned carbon-ion beam therapy in the head and neck
Abstract
OBJECTIVE: Carbon-ion radiotherapy (CIRT) has demonstrated success in treating radioresistant disease within the head and neck, owing to its unique physical and radiobiological properties. Construction cost remains prohibitive; a center offering only a horizontal port may bridge this difficulty, but removal of the vertical port may prohibit treatment of disease near critical organs-at-risk. Building a center only containing a horizontal treatment port has been proposed as one method for cost savings.
METHODS: 20 complex cases of head and neck cancer previously treated with conventional CIRT were retrospectively planned using horizontal-port-only treatment incorporating non-coplanar treatment angles to achieve greater degrees of freedom. These were dosimetrically compared with the previous plans.
RESULTS: Comparable D95 coverage of both planning target volume and gross tumor volume with ability to meet organ-at-risk constraints were feasible with horizontal-port-only treatment. Collectively differences were noted in PTV D95, brain stem Dmax, contralateral eye Dmax and V10 Gy (RBE); further qualitative differences were noted on a plan-by-plan basis dependent on disease location.
CONCLUSION: Horizontal-port-only treatment employing non-coplanar angles was feasible for complicated head and neck disease typically treated with CIRT, though careful consideration is necessary on a plan-by-plan basis.
ADVANCES IN KNOWLEDGE: It is worth noting that non-coplanar approaches are not…
How strong is the evidence?
Evidence Hub reads this as a cohort study, done in people. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence.
Read the paper
Related studies
- In silico toxicology protocols
- QM7-X, a comprehensive dataset of quantum-mechanical properties spanning the chemical space of small organic molecules
- Quantum Informed Machine-Learning Potentials for Molecular Dynamics Simulations of CO2's Chemisorption and Diffusion in Mg-MOF-74
- In-silico strategies in nano-drug design: Bridging nanomaterials and pharmacological applications
- mRNA codon optimization with quantum computers
- The computational power of the human brain
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.