Dual-source versus single-source cardiac CT angiography: comparison of diagnostic image quality
Abstract
OBJECTIVE: Dual-source CT improves temporal resolution, and theoretically improves the diagnostic image quality of coronary artery examinations without requiring preexamination beta-blockade. The purpose of our study was to show the improved diagnostic image quality of dual-source CT compared with single-source CT despite the absence of preexamination beta-blockade in the dual-source CT group.
MATERIALS AND METHODS: We performed a retrospective analysis of consecutive patients who underwent coronary artery evaluation with either single-source CT or dual-source CT at our institution between February 2005 and October 2006. Examination reports were analyzed for the presence of image artifacts, and image quality was graded on a 3-point scale (no, mild, or severe artifact). Type of artifact (motion, calcium, quantum mottle) was also noted.
RESULTS: Examinations (339 single-source CT and 126 dual-source CT) of 465 patients were analyzed. Artifact was reported in 39.8% of examinations using single-source CT and in 29.4% of examinations using dual-source CT (p < 0.05). The number of examinations with motion artifact was significantly higher with single-source CT than with dual-source CT (15.9% vs 4.8%; p < 0.001) despite significantly higher heart rates in the dual-source CT group (59.4 +/- 8.4 vs 68.6 +/- 14.6 beats per minute; p < 0.001). No patients in the dual-source CT group received preexamination beta-blockade compared with 81% of patients in the single-source CT group. The…
How strong is the evidence?
Evidence Hub reads this as a cohort study, done in people. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence. Reported size: 465 participants or records.
Read the paper
Related studies
- In silico toxicology protocols
- QM7-X, a comprehensive dataset of quantum-mechanical properties spanning the chemical space of small organic molecules
- Quantum Informed Machine-Learning Potentials for Molecular Dynamics Simulations of CO2's Chemisorption and Diffusion in Mg-MOF-74
- In-silico strategies in nano-drug design: Bridging nanomaterials and pharmacological applications
- mRNA codon optimization with quantum computers
- The computational power of the human brain
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.