Comparison of residential power-frequency magnetic fields away from appliances in different countries
Abstract
The purpose of this paper is to review measurements of residential power-frequency magnetic fields made in different countries and to determine whether average magnetic fields away from appliances are higher in some countries than in others. The paper includes 27 studies reporting measurements of residential magnetic fields in samples of homes: 14 from North America, 5 from the United Kingdom, and 8 from other European countries. Various factors that might make the results from individual studies unrepresentative of average fields in the relevant country are identified and discussed. Because distributions of magnetic fields generally are approximately log-normal, they are summarised by their geometric means. The best estimate of the geometric means of long-term average background fields in the United States is 60-70 nT and in the United Kingdom approximately 36-39 nT. In other countries, there are insufficient studies to draw firm conclusions on average fields. Measurements of personal exposure are higher than measurements of background fields, perhaps because they include exposures from appliances and other sources in the home. The ratio of personal exposure to background field seems, on average, to be approximately 1.4.
How strong is the evidence?
Evidence Hub reads this as a meta-analysis, done in people. Its evidence level is 1 of 5 (Highest · pooled evidence). Pooled evidence from several studies sits at the top of the evidence pyramid.
Read the paper
Related studies
- Preliminary Toxicity Analysis of 3DCRT versus IMRT on the High Dose Arm of the RTOG 0126 Prostate Cancer Trial
- Adaptive Radiotherapy for Head and Neck Cancer: Initial Clinical Outcomes from a Prospective Trial
- American Association of Physicists in Medicine Task Group 263: Standardizing Nomenclatures in Radiation Oncology
- Motion Management Strategies and Technical Issues Associated with Stereotactic Body Radiotherapy of Thoracic and Upper Abdominal Tumors: A Review from NRG Oncology
- High-dose-rate interstitial brachytherapy as a monotherapy for localized prostate cancer: treatment description and preliminary results of a phase I/II clinical trial
- Highly efficient training, refinement, and validation of a knowledge-based plan quality control system for radiotherapy clinical trials
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.