Highly sensitive electrochemical sensor based on La3+-doped Co3O4 nanocubes for determination of sudan I content in food samples
Abstract
In current research, a sensitive screen printed electrochemical sensor on the basis of La3+-doped Co3O4 nanocubes was fabricated to determine sudan I. The electrochemical performance of sudan I at this sensor was investigated in detail, presenting that this sensor had electrocatalytic behavior for oxidizing sudan I due to the significant peak current enhancement and the dropping of oxidation overpotential. Under the optimum conditions, the linear response range for sudan I concentrations by the modified sensor was 0.3-300.0 µM, and detection limit was 0.05 µM. Lastly, the suggested technique was also studied as a selective, easy, and exact electrochemical sensor to determine sudan I in food samples, including chili powder, tomato paste, and ketchup sauce.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target