A Concise and Systematic Review on Non-Invasive Glucose Monitoring for Potential Diabetes Management
Abstract
The current standard of diabetes management depends upon the invasive blood pricking techniques. In recent times, the availability of minimally invasive continuous glucose monitoring devices have made some improvements in the life of diabetic patients however it has its own limitations which include painful insertion, excessive cost, discomfort and an active risk due to the presence of a foreign body under the skin. Due to all these factors, the non-invasive glucose monitoring has remain a subject of research for the last two decades and multiple techniques of non-invasive glucose monitoring have been proposed. These proposed techniques have the potential to be evolved into a wearable device for non-invasive diabetes management. This paper reviews research advances and major challenges of such techniques or methods in recent years and broadly classifies them into four types based on their detection principles. These four methods are: optical spectroscopy, photoacoustic spectroscopy, electromagnetic sensing and nanomaterial based sensing. The paper primarily focuses on the evolution of non-invasive technology from bench-top equipment to smart wearable devices for personalized non-invasive continuous glucose monitoring in these four methods. With the rapid evolve of wearable technology, all these four methods of non-invasive blood glucose monitoring independently or in combination of two or more have the potential to become a reality in the near future for efficient,…
How strong is the evidence?
Evidence Hub reads this as a systematic review, done in people. Its evidence level is 1 of 5 (Highest · pooled evidence). Pooled evidence from several studies sits at the top of the evidence pyramid.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.