Acute Effects of an "Energy Drink" on Short-Term Maximal Performance, Reaction Times, Psychological and Physiological Parameters: Insights from a Randomized Double-Blind, Placebo-Controlled, Counterbalanced Crossover Trial
Abstract
The current study examined the relationships between the effects of consuming a caffeine-containing "energy drink" upon (i) short-term maximal performance, (ii) reaction times, and (iii) psychological factors (i.e., mood state, ratings of perceived exertion (RPE), and affective load) and on physiological parameters (i.e., blood pressure and blood glucose). A randomized, double-blind, placebo-controlled, counterbalanced crossover design was implemented in this study. Nineteen male physical-education students (age: 21.2 ± 1.2 years; height: 1.76 ± 0.08 m; body-mass: 76.6 ± 12.6 kg) performed two test sessions: after drinking the "Red Bull' beverage (RB) and after drinking a placebo (PL). One hour after ingestion of each drink, resting blood glucose and blood pressure were measured and the participants completed the Profile of Mood States questionnaire. Then, after a 5-min warm-up, simple visual reaction time and handgrip force were measured, and the 30-s Wingate test was performed. Immediately after these tests, the RPE, blood glucose, and blood pressure were measured, and the affective load was calculated. Differences between treatments were assessed using two-way repeated measures analyses of variance and paired t-tests, as appropriate. Relationships between the test variables were assessed using Bland-Altman correlations. Significant (i) improvements in peak and mean power output, handgrip force, pre- and post-exercise blood glucose, blood pressure, and vigor and (ii)…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 2 of 5 (High · randomized trial). Randomized trials of a reasonable size are the strongest single-study design.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.