A comparative study of two methods for attaining constant alcohol levels
Abstract
Aims: Alcohol effects or drug-alcohol interactions are preferably studied at constant blood levels. To achieve pseudo-steady state levels, various methods are used, which usually produce adequate averages but variable individual concentration profiles. The aim was to compare two modes of alcohol administration: a 'two-step prekinetic procedure' and a 'clamping method'.
Methods: The two-step prekinetic procedure started with determination of individual pharmacokinetic (PK) parameters, during a prestudy occasion. Individual infusion regimens were calculated afterwards, based on a pseudo-steady state breath alcohol concentration (BrAC) of 0.65 g l(-1) and applied on a separate occasion. For the clamping procedure, a spreadsheet-based paradigm was developed using BrAC-guided adjustments of infusion rates, to maintain stable BrAC levels of 0.6 g l(-1).
Results: The mean BrAC during clamping [0.61 g l(-1), 95% confidence interval (CI) 0.58, 0.63] did not differ from its intended level of 0.6 g l(-1) (1.0% on average). In contrast, the mean BrAC during the prekinetic procedure was significantly lower than the 0.65 g l(-1) set-point (0.59 g l(-1), 95% CI 0.54, 0.63) and deviated from this target by 9.7% on average. The clamping method also showed less variation between subjects [coefficient of variation (CV) 6.2%] compared with the prekinetic procedure (CV 14.6%).
Conclusions: Although the two methods differ considerably in their approach, clamping of BrAC resulted in more accurate…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 2 of 5 (High · randomized trial). Randomized trials of a reasonable size are the strongest single-study design.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.