Fructose administration increases intraoperative core temperature by augmenting both metabolic rate and the vasoconstriction threshold
Abstract
Background: The authors tested the hypothesis that intravenous fructose ameliorates intraoperative hypothermia both by increasing metabolic rate and the vasoconstriction threshold (triggering core temperature).
Methods: Forty patients scheduled to undergo open abdominal surgery were divided into two equal groups and randomly assigned to intravenous fructose infusion (0.5 g . kg(-1) . h(-1) for 4 h, starting 3 h before induction of anesthesia and continuing for 4 h) or an equal volume of saline. Each treatment group was subdivided: Esophageal core temperature, thermoregulatory vasoconstriction, and plasma concentrations were determined in half, and oxygen consumption was determined in the remainder. Patients were monitored for 3 h after induction of anesthesia.
Results: Patient characteristics, anesthetic management, and circulatory data were similar in the four groups. Mean final core temperature (3 h after induction of anesthesia) was 35.7 degrees +/- 0.4 degrees C (mean +/- SD) in the fructose group and 35.1 degrees +/- 0.4 degrees C in the saline group (P = 0.001). The vasoconstriction threshold was greater in the fructose group (36.2 degrees +/- 0.3 degrees C) than in the saline group (35.6 degrees +/- 0.3 degrees C; P < 0.001). Oxygen consumption immediately before anesthesia induction in the fructose group (214 +/- 18 ml/min) was significantly greater than in the saline group (181 +/- 8 ml/min; P < 0.001). Oxygen consumption was 4.0 l greater in the fructose patients…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 2 of 5 (High · randomized trial). Randomized trials of a reasonable size are the strongest single-study design.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.