Dose-dependent onset and cessation of action of inhaled budesonide on exhaled nitric oxide and symptoms in mild asthma
Abstract
Background: Dose dependent anti-inflammatory effects of inhaled corticosteroids in asthma are difficult to demonstrate in clinical practice. The anti-inflammatory effect of low dose inhaled budesonide on non-invasive exhaled markers of inflammation and oxidative stress were assessed in patients with mild asthma.
Methods: 28 patients entered a double blind, placebo controlled, parallel group study and were randomly given either 100 or 400 micro g budesonide or placebo once daily, inhaled from a dry powder inhaler (Turbohaler), for 3 weeks followed by 1 week without treatment. Exhaled nitric oxide (NO), exhaled carbon monoxide (CO), nitrite/nitrate, S-nitrosothiols, and 8-isoprostanes in exhaled breath condensate were measured four times during weeks 1 and 4, and once a week during weeks 2 and 3.
Results: A dose-dependent speed of onset and cessation of action of budesonide was seen on exhaled NO and asthma symptoms. Treatment with 400 micro g/day reduced exhaled NO faster (-2.06 (0.37) ppb/day) than 100 micro g/day (-0.51 (0.35) ppb/day; p<0.01). The mean difference between the effect of 100 and 400 micro g budesonide was -1.55 ppb/day (95% CI -2.50 to -0.60). Pretreatment NO levels were positively related to the subsequent speed of reduction during the first 3-5 days of treatment. Faster recovery of exhaled NO was seen after stopping treatment with budesonide 400 micro g/day (1.89 (1.43) ppb/day) than 100 micro g/day (0.49 (0.34) ppb/day, p<0.01). The mean difference between…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence. Reported size: 28 participants or records.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.