Safety and Efficacy of Sustained Automated Insulin Delivery Compared With Sensor and Pump Therapy in Adults With Type 1 Diabetes at High Risk for Hypoglycemia: A Randomized Controlled Trial
Abstract
OBJECTIVE Assess the safety and efficacy of automated insulin delivery (AID) in adults with type 1 diabetes (T1D) at high risk for hypoglycemia. RESEARCH DESIGN AND METHODS Participants were 72 adults with T1D who used an insulin pump with Clarke Hypoglycemia Perception Awareness scale score >3 and/or had severe hypoglycemia during the previous 6 months confirmed by time below range (TBR; defined as sensor glucose [SG] reading <70 mg/dL) of at least 5% during 2 weeks of blinded continuous glucose monitoring (CGM). Parallel-arm, randomized trial (2:1) of AID (Tandem t:slim ×2 with Control-IQ technology) versus CGM and pump therapy for 12 weeks. The primary outcome was TBR change from baseline. Secondary outcomes included time in target range (TIR; 70–180 mg/dL), time above range (TAR), mean SG reading, and time with glucose level <54 mg/dL. An optional 12-week extension with AID was offered to all participants. RESULTS Compared with the sensor and pump (S&P), AID resulted in significant reduction of TBR by −3.7% (95% CI −4.8, −2.6), P < 0.001; an 8.6% increase in TIR (95% CI 5.2, 12.1), P < 0.001; and a −5.3% decrease in TAR (95% CI −87.7, −1.8), P = 0.004. Mean SG reading remained similar in the AID and S&P groups. During the 12-week extension, the effects of AID were sustained in the AID group and reproduced in the S&P group. Two severe hypoglycemic episodes occurred using AID. CONCLUSIONS In adults with T1D at high risk for hypoglycemia, AID reduced the risk for…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 2 of 5 (High · randomized trial). Randomized trials of a reasonable size are the strongest single-study design. Reported size: 72 participants or records.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.