No Benefit to Sensor-guided Balancing Compared With Freehand Balancing in TKA: A Randomized Controlled Trial
Abstract
Abstract Background Soft tissue balancing in TKA has traditionally relied on surgeons’ subjective tactile feedback. Although sensor-guided balancing devices have been proposed to provide more objective feedback, it is unclear whether their use improves patient outcomes. Questions/purposes We conducted a randomized controlled trial (RCT) comparing freehand balancing with the use of a sensor-guided balancing device and evaluated (1) knee ROM, (2) patient-reported outcome measures (PROMs) (SF-12, WOMAC, and Knee Society Functional Scores [KSFS]), and (3) various surgical and hospital parameters (such as operative time, length of stay [LOS], and surgical complications) at a minimum of 2 years of follow-up. Methods A total of 152 patients scheduled for primary TKA were recruited and provided informed consent to participate in this this study. Of these, 22 patients were excluded preoperatively, intraoperatively, or postoperatively due to patient request, surgery cancellation, anatomical exclusion criteria determined during surgery, technical issues with the sensor device, or loss to follow-up. After the minimum 2-year follow-up was accounted for, there were 63 sensor-guided and 67 freehand patients, for a total of 130 patients undergoing primary TKA for osteoarthritis. The procedures were performed by one of three fellowship-trained arthroplasty surgeons (RPS, HJC, JAG) and were randomized to either soft tissue balancing via a freehand technique or with a sensor-guided balancing…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 2 of 5 (High · randomized trial). Randomized trials of a reasonable size are the strongest single-study design. Reported size: 152 participants or records.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.