Electrical vestibular stimulation to improve balance in older adults: a pilot randomized controlled trial
Abstract
Falls are the leading cause of injury-related hospitalizations among older adults, often linked to vestibular dysfunction. While vestibular rehabilitation therapy is a standard intervention, designed to compensate for vestibular impairment with proprioceptive and visual cues, potential cumulative effects of noisy Electrical Vestibular Stimulation (nEVS) on balance improvement in older adults are not well understood. This study evaluated the efficacy of cumulative nEVS dosing in improving static balance, its potential mechanisms, and clinical significance. A single-blind, pilot randomized controlled trial enrolled 40 older adults (mean age: 77.7 ± 11.8 years). Participants were randomly assigned to a Stimulation group (nEVS intervention) or Sham group. The nEVS regimen included low-amplitude wideband stimulation (± 0.35 mA, 0.001–300 Hz) for 20 min, three times weekly for six weeks. Balance performance was assessed immediately before and after nEVS using a head-mounted sensor to measure physiological vibration acceleration (‘Phybrata’) power as a measure of postural stability in four conditions: Floor Eyes Open, Floor Eyes Closed, Foam Eyes Open, and Foam Eyes Closed. Follow-ups occurred at 3 months and 6 months post-intervention. The Stimulation group exhibited significant and sustained reductions in Phybrata power with improvements observed as early as Session 3 and persisting through 6 months in Foam EC. Additionally, the Sham group demonstrated smaller reductions in…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 2 of 5 (High · randomized trial). Randomized trials of a reasonable size are the strongest single-study design. Reported size: 40 participants or records.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.