Effect of Visual Feedback on Force Application in Semmes-Weinstein Monofilament Testing: A Randomized Controlled Trial
Abstract
Objectives: This study aimed to compare the effectiveness of traditional simulation training (TST) and visual feedback training (VFT) in improving force accuracy and consistency during the application of the Semmes-Weinstein Monofilament Test (SWMT) among occupational therapy students.
Materials and Methods: A randomized controlled trial was conducted with 52 senior-year occupational therapy students (TST:n = 25; VFT:n = 27). All participants received standardized theoretical instruction before undergoing either TST or VFT. Pre- and post-training assessments were conducted using a high-precision force sensor. Main outcome measures included maximum applied force (MaxF1–3), absolute error, contact duration (T1–3), and inter-application intervals (L1–2). Non-parametric tests and effect sizes (r) were used for statistical comparisons.
Results: Post-training comparisons revealed significantly greater force consistency in the VFT group compared to TST: MaxF1 (p = 0.04, r = 0.273), MaxF2 (p = 0.02, r = 0.318), MaxF3 (p = 0.03, r = 0.302). Absolute error increased in TST (MaxF2: +0.25g), while it decreased in VFT (MaxF2: –0.20g). Touch durations (T1–T3) significantly improved only in the VFT group (p < 0.001), with large effect sizes (r= 0.721 to 0.772). No significant improvements were observed in TST.
Conclusion: VFT enhanced students’ ability to apply consistent and accurate force during SWMT compared to TST. These findings highlight the value of integrating objective feedback…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence. Reported size: 27 participants or records.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.