Effects of foam rolling and static stretching on ankle dorsiflexion and jumping ability: a randomized controlled trial
Abstract
This study aimed to assess the impact of a 5-week intervention that combined foam rolling (FR) and static stretching (SS) on ankle dorsiflexion range of motion (ROM). Furthermore, the study evaluated the influence of the intervention on leaping ability utilizing the counter-movement jump test (CMJ). Random assignment was used to allocate fifty-one amateur sports enthusiasts to either the foam rolling + static stretching (FR-SS) group (n = 22; age: 19.3 ± 6.87 years; height: 171 ± 7.91 cm; weight: 66.7 ± 9.52 kg) or the static stretching (SS) group (n = 29; age: 18.5 ± 4.60 years; height: 171 ± 11.5 cm; weight: 68.3 ± 16 kg). A baseline assessment (T0) and an assessment following the 5-week intervention (T1) were carried out. An inertial sensor was used to quantify the ankle joint ROM, and an optical detecting system was used to measure the CMJ performance. Significant differences were found between T0 and T1 in the FR-SS group. Significant group-by-time interaction effects (F = 14.44; p < 0.001, η2p = 0.128) and between-subject effects (F = 53.5; p < 0.001, η2p = 0.353) were found. Significant enhancements in CMJ performance (p < 0.01) were noted after the intervention in the FF-SS group. A similar trend was not observed in the SS group. Our findings suggest that a 5-week intervention combining FR with SS leads to greater improvements on ROM and angular velocity of the ankle joint, and on CMJ performance compared to SS alone. If further research confirms these results, FR…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence. Reported size: 29 participants or records.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.