FIT for purpose: study protocol for a randomized controlled trial to personalize surveillance colonoscopy for individuals at elevated risk of colorectal cancer
Abstract
Purpose There is increasing demand for colorectal cancer (CRC) surveillance, but healthcare capacity is limited. The burden on colonoscopy resources could be reduced by personalizing surveillance frequency using the fecal immunochemical test (FIT). This study will determine the safety, cost-effectiveness, and patient acceptance of using FIT to extend surveillance colonoscopy intervals for individuals at elevated risk of CRC. Methods This multicenter, prospective, randomized controlled trial will invite participants who are scheduled for surveillance colonoscopy (due to a personal history of adenomas or a family history of CRC) and who have returned a low fecal hemoglobin (< 2 μg Hb/g feces; F-Hb) using a two-sample FIT (OC Sensor, Eiken Chemical Company) in the prior 3 years. A total of 1344 individuals will be randomized to either surveillance colonoscopy as scheduled or delayed by 1 or 2 years for individuals originally recommended a 3- or 5-year surveillance interval, respectively. The primary endpoint is incidence of advanced neoplasia (advanced adenoma and/or CRC). Secondary endpoints include cost-effectiveness and consumer acceptability of extending surveillance intervals, determined using surveys and discrete choice experiments. Conclusion This study will establish the safety, cost-effectiveness, and acceptability of utilizing a low FIT Hb result to extend colonoscopy surveillance intervals in a cohort at elevated risk for CRC. This personalized approach to CRC…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 2 of 5 (High · randomized trial). Randomized trials of a reasonable size are the strongest single-study design. Reported size: 1,344 participants or records.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.