Performance of a dual-hormone closed-loop system versus insulin-only closed-loop system in adolescents with type 1 diabetes. A single-blind, randomized, controlled, crossover trial
Abstract
Objective To assess the efficacy and safety of a dual-hormone (DH [insulin and glucagon]) closed-loop system compared to a single-hormone (SH [insulin only]) closed-loop system in adolescents with type 1 diabetes. Methods This was a 26-hour, two-period, randomized, crossover, inpatient study involving 11 adolescents with type 1 diabetes (nine males [82%], mean ± SD age 14.8 ± 1.4 years, diabetes duration 5.7 ± 2.3 years). Except for the treatment configuration of the DiaCon Artificial Pancreas: DH or SH, experimental visits were identical consisting of: an overnight stay (10:00 pm until 7:30 am), several meals/snacks, and a 45-minute bout of moderate intensity continuous exercise. The primary endpoint was percentage of time spent with sensor glucose values below range (TBR [10.0 mmol/L]) 28.1 [18.1, 49.8] vs. 23.3 [12.3, 27.2]%, p=0.10. Mean ( ± SD) glucose was higher during DH than SH (8.7 ( ± 3.2) vs. 8.1 ( ± 3.0) mmol/L, p<0.001) but coefficient of variation was similar (34.8 ( ± 6.8) vs. 37.3 ( ± 8.6)%, p=0.20). The average amount of rescue carbohydrates was similar between DH and SH (6.8 ( ± 12.3) vs. 9.5 ( ± 15.4) grams/participant/visit, p=0.78). Overnight, TIR was higher, TAR was lower during the SH visit compared to DH. During and after exercise (4:30 pm until 7 pm) the SH configuration produced higher TIR, but similar TAR and TBR compared to the DH configuration. Conclusions DH and SH performed similarly in adolescents with type 1 diabetes during a 26-hour…
How strong is the evidence?
Evidence Hub reads this as a randomized trial, done in people. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence. Reported size: 11 participants or records.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.