High-resolution noncontact charge-density mapping of endocardial activation
Abstract
Background: Spatial resolution in cardiac activation maps based on voltage measurement is limited by far-field interference. Precise characterization of electrical sources would resolve this limitation; however, practical charge-based cardiac mapping has not been achieved.
Methods: A prototype algorithm, developed from first principles of electrostatic field theory, derives charge density (CD) as a spatial representation of the true sources of the cardiac field. The algorithm processes multiple, simultaneous, noncontact voltage measurements within the cardiac chamber to inversely derive the global distribution of CD sources across the endocardial surface.
Results: Comparison of CD to an established computer-simulated model of atrial conduction demonstrated feasibility in terms of spatial, temporal, and morphologic metrics. Inverse reconstruction matched simulation with median spatial errors of 1.73 mm and 2.41 mm for CD and voltage, respectively. Median temporal error was less than 0.96 ms and morphologic correlation was greater than 0.90 for both CD and voltage. Activation patterns observed in human atrial flutter reproduced those established through contact maps, with a 4-fold improvement in resolution noted for CD over voltage. Global activation maps (charge density-based) are reported in atrial fibrillation with confirmed reduction of far-field interference. Arrhythmia cycle-length slowing and termination achieved through ablation of critical points demonstrated in the…
How strong is the evidence?
Evidence Hub reads this as a clinical trial, done in people. Its evidence level is 3 of 5 (Moderate · trial / cohort / secondary analysis). Trials without a large randomized design, cohorts and secondary analyses give moderate evidence.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.