In vivo measurement of facet joint nitric oxide in patients with chronic low back pain
Abstract
STUDY DESIGN: Prospective case-control study testing a new diagnostic method.
OBJECTIVE: The aim of the present study was to investigate the concentration of nitric oxide (NO) in the perifacetal region in patients with chronic low back pain and healthy controls.
SUMMARY OF BACKGROUND DATA: Facet joint arthrosis may be a pain source in chronic back pain. Increased concentrations of NO, an oxygen-free radical, have been demonstrated in temporomandibular and knee joints with osteoarthritis.
PATIENTS AND METHODS: Patients with at least 6 months' duration of chronic low back pain and signs of facet joint osteoarthrosis (n = 24) and healthy volunteers (n = 7) were included. A detailed questionnaire, including visual analogue scale, was completed before and 6 weeks after the measurements. NO was measured with a custom-designed electrochemical real-time NO sensor inserted under fluoroscopic guidance. All patients received corticosteroids and local anesthetics after NO measurements.
RESULTS: NO measurements were obtained from all participants. No adverse effects were noted. The patients with chronic low back pain demonstrated higher concentrations of NO in the perifacetal region compared with healthy controls (1.66 +/- 0.28 vs. 0.46 +/- 0.14 nmol/L, P = 0.007). No association between NO concentration and pain duration or pain level was detected. Patients with a positive response to local anesthetics and corticosteroid injection (defined as a >or=20 mm reduction of visual analogue…
How strong is the evidence?
Evidence Hub reads this as a case-control, done in people. Its evidence level is 4 of 5 (Low · observational). Observational designs can show an association but not prove cause. Reported size: 24 participants or records.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.