Sensor-derived multidimensional gait domains mediate the association between intrinsic capacity impairment and fall risk in community-dwelling older adults: a cross-sectional study
Abstract
Background Falls are a leading cause of injury and functional decline in older adults. Intrinsic capacity (IC) impairment has emerged as an important predictor of fall risk, yet the biomechanical pathways linking IC decline to falls remain uncharacterized. Whether sensor-derived multidimensional gait domains serve as domain-specific indirect pathways in the IC-fall association has not been examined. Methods In this cross-sectional study of 813 community-dwelling adults (aged ≥60 years), IC impairment and a 12-month self-reported fall history were assessed. Gait was quantified using a wearable multi-sensor system, with nine parameters summarized into three domains: pace, gait phase, and kinetics. Logistic regression-based mediation analysis was used to test the indirect effects of gait domains on the association between IC and falls. Results Higher IC impairment was independently associated with greater odds of falling after full adjustment (OR = 1.36, 95% CI: 1.11–1.66). Among gait domains, pace (OR = 0.75, 95% CI: 0.56−0.99) and kinetics (OR = 0.76, 95% CI: 0.59−0.99) were independently associated with lower fall odds, whereas gait phase was not. Mediation analyses indicated that pace and kinetics partially mediated the IC-fall association, accounting for 18.76% and 10.64% of the total effect respectively, with gait phase showing no significant indirect effect. Conclusions These exploratory findings suggest that multidimensional gait assessment may complement IC screening…
How strong is the evidence?
Evidence Hub reads this as a cross-sectional, done in people. Its evidence level is 4 of 5 (Low · observational). Observational designs can show an association but not prove cause.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.