Associations Between HbA1c and Glucose Time in Range Using Continuous Glucose Monitoring in Type 1 Diabetes: Cross-Sectional Population-Based Study
Abstract
Continuous glucose monitoring (CGM) introduces novel indicators of glycemic control. This cross-sectional study, based on the Swedish National Diabetes Register, examines 27,980 adults with type 1 diabetes. It explores the relationships between HbA1c (glycated hemoglobin) and various CGM-derived metrics, including TIR (time in range, representing the percentage of time within the range of 4–10 mmol/l for 2 weeks), TAR (time above range), TBR (time below range), mean glucose, standard deviation (SD), and coefficient of variation (CV). Pearson correlation coefficients and linear regression models were utilized for estimation. The analysis included 46% women, 30% on insulin pump, 7% with previous coronary heart disease and 64% with retinopathy. Mean ± SD values were age 48 ± 18 years, diabetes duration 25 ± 16 years, HbA1c 58.8 ± 12.8 mmol/mol, TIR 58.8 ± 19.0%, TAR 36.3 ± 20.0%, TBR 4.7 ± 5.4%, mean sensor glucose 9.2 ± 2.0 mmol/l, SD 3.3 ± 1.0 mmol/l, and CV 36 ± 7%. The overall association between HbA1c and TIR was − 0.71 (Pearson’s r), with R2 0.51 in crude linear regression and 0.57 in an adjusted model. R2 values between HbA1c and CGM mean glucose were 0.605 (unadjusted) 0.619 (adjusted) and TAR (unadjusted 0.554 and fully adjusted 0.568, respectively), while fully adjusted R2 values were 0.458, 0.175 and 0.101 between HbA1c and CGM SD, CGM CV and TBR, respectively. This descriptive study demonstrates that the degree of association between HbA1c and new and readily…
How strong is the evidence?
Evidence Hub reads this as a cross-sectional, done in people. Its evidence level is 4 of 5 (Low · observational). Observational designs can show an association but not prove cause. Reported size: 27,980 participants or records.
Read the paper
Related studies
- Nano Biosensors: Properties, applications and electrochemical techniques
- Electrochemically Synthesized MIP Sensors: Applications in Healthcare Diagnostics
- Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment
- Electrochemical determination of rutin by using NiFe2O4 nanoparticles-loaded reduced graphene oxide
- Application of Polyoxometalate-based composites for sensor systems: A review
- Sensitive Electrochemical and Thermal Detection of Human Noroviruses Using Molecularly Imprinted Polymer Nanoparticles Generated against a Viral Target
Go deeper in Evidence Hub
Evidence Hub adds a study data sheet (design, sample size, evidence level, key numbers), an AI summary and a chat grounded in the paper's text.